Power Source:
|
AC : 110 V - 120 V or 220 V - 240 V (selectable), 50 / 60 Hz
|
|
DC : +24 V, M3 screw terminal*2
|
Power Consumption (AC):
|
|
Non-operation mode (standby)
|
14 W
|
Under normal operating conditions according to IEC60065
|
175 W
|
With rated output signal
|
680 W
|
Current Consumption (DC):
|
|
Non-operation mode (standby)
|
0.1 A
|
Under normal operating conditions according to IEC60065
|
8 A
|
With rated output signal
|
20 A
|
Rated Output:
|
240 W
|
Frequency Response:
|
50 Hz - 15 kHz, -3 �3 dB
|
Distortion:
|
Less than 1 % at 1 kHz rated output
|
Signal- to-Noise Ratio:
|
More than 60 dB
|
Volume Control:
|
|
LINE IN
|
0 dB to �� (off)
|
Operation On/Off Control (OPERATE ON / OFF):
|
No-voltage make contact input, open voltage : +5 V DC, short-circuit current : under 1 mA, M3 screw terminal*3
|
Operation Link Control (OPERATE LINK):
|
Open collector output, withstand voltage : +30 V DC, operating current : under 50 mA, M3 screw terminal*3
|
Level Meter:
|
5 points, -30 / -20 / -15 / -8 / 0
|
Cooling Fan:
|
3 modes, Stop / Low speed / High speed
|
Operating Temperature:
|
0 �C - 45 �C
|
Dimensions:
|
420 mm (W) x 146 mm (H) x 394 mm (D) [Height includes rubber feet and depth includes projections such as rear protect cover.]
|
Weight (Approx.):
|
15 kg
|
Finish:
|
Panel : Gun Metallic painting (ABS Resin)
|
|
Case : brack painting, Munsell N1 or equivalent (steel plate)
|
Accessories:
|
AC power codes (x 2), Rack mounting brackets, Operating instructions
|